Analysis Unit Test Method LIMIT
AW400 AW402 AW406 AW410
Density@15°c Kg/m3 ASTM D1298 report 775 MIN report report
Distillation:
I.B.P °C ASTM D86 45 min 142-158 62 min 55 min
10% Evaporated °C ASTM D86 158 min
50% Recovered °C ASTM D86 80 approx 179 max 63 min
71 max
71 min
83 max
90% Recovered °C ASTM D86 120 approx 194 max 64 min
74 max
81 min
99 max
Dry Point °C ASTM D86 150 approx 198 max 80 max 11 max
Recovery Vol% ASTM D86 98 min 98 min 98 min
Residue Vol% ASTM D86 1.5 max
Loss Vol% ASTM D86 1 max 1 max 1 max
Colour Saybolt ASTM D156 25 min 25 min 25 min 25 min
Odour Merchantable Merchantable Merchantable Merchantable
Flash Point tag °C ASTM D56 38 min
Corrosion-3hrs@100°C ASTM D130 1a 1a 1a 1a
Sulphur Total Wt% ASTM D1266 0.01 max 0.1 max 0.05 max 0.01 max
Doctor Test ASTM D4952 Negatvive Negatvive Negatvive Negatvive
Aromatic Content Vol% ASTM D1319 30 min 20 max 7 max report
Gum Existent Mg/100ml ASTM D 391 5 max
Neutrality BS.245 Pass
Acidity of Residue ASTM D1093 Pass